NEI
AEMC® Instruments (Dover , New Hampshire)
AEMC® Instruments

Alicate Multimétrico Testador de Aterramento

  • Alicate Multimétrico Testador de Aterramento
  • Alicate Multimétrico Testador de Aterramento

Descrição do produto

The Ground Resistance Tester Models 6416 and 6417 measure ground rod and grid resistance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting the ground system under test or de-energizing them. Models 6416 and 6417 simply clamp around the ground conductor or rod and measure the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured. | Two new features unique to AEMC® are test frequency selection and ground voltage indication. The ability to select the test frequency provides more accurate results in inductive environments. The inductance can also be measured and displayed. Displaying voltage derived from current and resistance measurements provides an extra level of safety for the user, indicating a potential dangerous touch condition. Both models include a current measurement function. The probe’s high sensitivity enables measurement of leakage current flowing to ground or circulating in ground loops from 0,2mA to 40A and resistances from 0,01 to 1500 Ohm. | Both models offer battery life information at power-up and Auto-Off for power management. Additional features are also displayed on the large OLED display to ensure precise measurements. The Buzzer and Auto Power Off features may be disabled from the push-buttons at any time. | Both offer an alarm function and a data storage function. In the Alarm mode, the probe will audibly and visually indicate if the reading is beyond the user programmed set point. The user may have the alarm activate above or below the set point. This alarm feature permits quick field checks where only “pass” or “fail” readings are required. | The data storage function enables the user to conduct field surveys, and to retrieve and analyze the readings at a later time. The alarm settings and stored data are saved when the ground tester is turned off. When using the FREE DataView® software, the 6417 provides Bluetooth transmission to a PC for analysis and report generation.

Ground voltage is displayed to alert user to potential unsafe conditions|Large multi-function, bright yellow organic display (OLED) usable in all lighting conditions|Display in Standard mode (1 screen) or Advanced mode (3 screens)|Selectable test frequency improves accuracy in inductive environments|Differentiates between loop and ground resistance measurements|Data storage (Q and/or A, with time-stamping) Model 6416: stores up to 300 measurements Model 6417: stores up to 2000 measurements|Displays stored measurements on the OLED display or by Bluetooth to a PC or the Android based mobile application. (model 6417)|Easy clamp opening by a force compensation trigger system|Large jaw design, 1,38" (35mm) accommodating up to 1000 kcmil cables|Alarm function with adjustable set point and buzzer for quick field checks|Rugged Lexan® head and body construction resists breakage|Alarm settings and stored memory information saved during shutdown|NOISE icon and buzzer alert user to presence of dangerous voltage and current levels|Automatic Hold of measurement when jaw is opened|Data Storage: 300 measurements|Android™ application provides configuration real-time data review, geolocation and e-mailing of test results


Modelos

* - Clique no respectivo modelo para mais informações.
Modelo* Abertura da Garra Categoria de medição Certificações Dimensões Gerais Faixa de Medição Fonte de Energia Frequência Grandeza Medida Medição de Indutância Normas Peso Precisão Resolução Temp. de Operação Tensão de Aterramento Tipo Umidade Admiss. Unidade de Medição
6416 35 mm CAT IV EN 61010-1 (Ed. 2 of 2001); 600V CAT IV 55x9x262 mm Corrente: 0,2mA to 40A Battery life: 12 hours, or 14.400 30-second measurements approx Frequência de Medição selecionável: 50, 60, 128 or 2083 Hz Corrente 10 to 500 µH CE 935 g Série (Resistência de Aterramento) 0,10 ~ 0,99 Ohm = ±1,5% ±0,01O Série (Resistência de Aterramento) 50,0 to 99,5 Ohm = 0,5 Ohm -20 ~ 55 °C 0,1 to 75,0 VAC Ground Resistance Teste 10% ~ 90% RH Ampère (A)
6417 35 mm CAT IV EN 61010-1 (Ed. 2 of 2001); 600V CAT IV 55x9x262 mm Corrente: 0,2mA to 40A 4x1,5V LR6 (AA) Alkaline batteries or 4 NiMH batteries Frequência de Medição selecionável: 50, 60, 128 or 2083 Hz Corrente 10 to 500 µH CE 935 g Série (Corrente) 100,0 to 299,0mA and 0,300 to 0,990A = ±2% ±1mA Série (Corrente) 0,200 to 0,999mA = 1µA -20 ~ 55 °C 0,1 to 75,0 VAC Ground Resistance Teste 10% ~ 90% RH Ampère (A)

Envie sua cotação para a empresa

Seus dados serão enviados às empresas para que elas retornem sua cotação.