NEI
AEMC® Instruments (Dover , New Hampshire)
AEMC® Instruments

Analisador, Medidor e Registrador de Qualidade de Energia - Modelo 8333

  • Analisador, Medidor e Registrador de Qualidade de Energia - Modelo 8333
  • Analisador, Medidor e Registrador de Qualidade de Energia - Modelo 8333

Descrição do produto

The PowerPad® III Model 8333 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three-phase networks. Current and voltage input terminals are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV. | The Model 8333 has memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 12 screen snapshots, up to 51 captured transients that contain four cycles for each active input, and 4,000 alarm events from up to 10 different parameters. Trend data can also be recorded for days, weeks or even months.

Unbalance: Yes|Peak: Yes|Phasor Display: Automatic|Languages: more than 26|Communication Interface: USB|True RMS single-, two- and three-phase measurements at 256 samples/cycle, plus DC|Real-time color waveforms|Automatic current probe recognition and scaling|Measures AC & DC volts, amps and power|Displays and captures voltage, current and power harmonics to 50th order, including direction, in real-time|Captures transients down to 1/256th of a cycle VA, VAR and W per phase and total|kVAh, VARh and kWh per phase and total|Neutral current calculated and displayed for three-phase|Transformer K-factor display|Power Factor, displacement PF display|Short and long term flicker display|Phase unbalance (current and voltage)|Harmonic Distortion (total bnd individual) from 1st to 50th|Alarms, surges and sags|Screen snapshot function captures waveforms or other information on the display|Includes FREE Data View software for configuring data storage, real-time display, analysis and report generation|Input Terminals: 4 voltage / 3 current|Inputs: 3 voltage / 3 current|Distribution Systems: 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W, 3p 5W, Split-Phase 2W & 3W, 2 ½ Element & Aron meters|Flicker: Pst|Record Mode: Yes|Trend Mode: Records up to 29 variables for several days to several years depending on selected storage rate|Alarm Mode 10 types; 4096 recorded; 2 sessions|Waveform Mode = Calculated: AN (RMS, DC, CF, PK+/-) and FK|Display: Color ¼ VGA TFT screen (320 x 240) diagonal 148mm Snapshots: 12|Sampling Frequency: 256 samples/cycle for trend recording|Data Storage: 2GB card for trend + 4MB partitioned for snapshot, transients and alarms


Modelos

* - Clique no respectivo modelo para mais informações.
Modelo* Aplicações Categoria de medição Certificações Dimensões Gerais Faixa de Medição Fonte de Energia Grandeza Medida Grau de Proteção Normas Peso Tipo Unidade de Medição
2136.10 Energy metering (kVAh, VARh, kWh) 1000V CAT III / 600V CAT IV IEC 61010 240 x 180 x 55 mm Voltage Ratio: up ~ 500kV Power Source: 9,6V NiMH rechargeable battery pack (included) Energia IP53 - non operating CE 1,95 kg Three-phase power quality analyzer V, A, W, VA, var, VAD, PF, DPF, cos ?, tan ?, Wh, varh, VAh, VADh, kW, kvar, PF, DPF, kWh, kvarh, kVAh, Factor K, Flicker